Page 27
800 Series
SECTION 5: TROUBLESHOOTING
Error Codes
If any of the errors listed below as “E001-E007”
are detected the message “Eror” will flash on
the display. To view the error or a list of errors
enter the Display Mode (see “Display Mode”
section of this manual). If a single error is
detected the code will be displayed in place of
the “Full/Fill AbCd” message. If there is more
than one error, the codes will alternate one after
the other.
“FULL/FILL AbCd”........................ No Errors
“E001”......................Validation Sensors Error
“E002”.............................. Tube Sensors Error
“E003”....................................... Coin Jammed
“E004”.........................................Payout Error
“E005”...........................................ROM Error
“E006”............................. Configuration Error
“E007”...........................Supply Voltage Error
The error codes listed below are displayed upon
occurrence:
“E 20” ...................................... Double Arrival
................................... (coins dropped too fast)
“E 88” .............A Payout sweeper arm is at the
..........end of stroke, re-align the sweeper arm.
“E 82” .................. VMC attempting to pay out
.................................coins from an empty tube
The following errors will require the changer to
be sent to a Coinco service centre for repair:
“E 21” ........................A to D Conversion fault
“E 22” ........................... Validation Opto Fault
................... or jammed coin in validation path
“E 25” & “E 26” ........ EC coil reading timeout
“E 27” & “E 28” ....... MF coil reading timeout
“E 29” .......................Stored air values corrupt
“E 40” ....................................TAU coil failure
“E 41” .......................................EC coil failure
“E 42” ...................................... MF coil failure
“E 90” ......................Acceptor memory failure