4.3 PRELIMINARY OPERATIONS, WASH AND SANITIZATION
Before starting the machine, it is necessary to thoroughly clean it and sanitize all parts in
contact with the product.
IMPORTANT:
Cleaning and sanitizing are important operations that should be carried out at the end of
every working day, with accuracy, in order to guarantee high quality and the observance of
all hygienic rules.
4.3.1 Preliminary cleanout
To clean the machine do as follows:
l Opening shut-off valve 346 on machine front side.
l Fill both cylinders with water using the special hose 351.
To use shower 351 placed on the top of the machine, withdraw the hose from its seat,
press the button and then the button you find on shower handle in order to open
water jet.
Before putting the shower back, shut it off and press or , drain water from
the hose by keeping down the button on shower handle.
l After pouring washing water, press the button for heating side and the button
for production side.
When programmed time has elapsed, the machine will automatically set at STOP position.
l By first turning the lever 502 and then lowering the handle 5, let all water come out of the cylinders.
l After emptying the freezing cylinder, (front lid is opened by lifting the lever 289 and pulling
it to the right) it is advisable to clean the cylinder with a bolt of water while keeping the
beater blocked in its seat.
l Disassemble then the machine by removing its parts.
Note:
As far as disassembling of the machine parts is concerned, please see instructions described at
section 6 "Cleanout, disassembling and reassembling of parts in contact with the product".
Wash the removed machine parts in luke warm (80-90 F) water and mild non-foaming detergent.
Scrub each of the parts with the cleaning brushes provided in the machines spare parts kit.
IMPORTANT
DO NOT use hot water on any of the plastic parts as this may result in damaging these parts.
351
Shower-head
502
5
289
346