EasyManua.ls Logo

Comelit 6801W - Advanced Monitor Configuration - Intercom; Intercom Call Programming; Selective Intercom Address Setup

Comelit 6801W
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Advanced monitor configuration
TAB. B
Code Dip switch ON S1 Code Dip switch ON S1
1 1
5 5
2 2 6 6
3 3 7 7
4 4 8 8
1) 2) 3)
Programming; set code,
table B
S1
S2 DIP
1 2 3 4 5 6
0 0 0 1 1 1
S2
1
x4
x10
Cancellation
S1
S2 DIP
1 2 3 4 5 6
1 1 1 1 1 1
S2
If the default settings (see table “Standard configuration for soft-touch keys”) do not reflect requirements, the keys can be
programmed dierently by carrying out the steps below.
At the end, set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting in the configuration tables "Advanced
monitor configuration"). In this dip switch setting, the keys control the programmed functions; the NON-programmed
keys control functions referred to on line 0000 (see table “Standard configuration for soft-touch keys”. Restore the user
code setting on S1, see addressing table.
Warning
Programming/deleting intercom address (selective intercom only)
Programming for intercom call
General intercom: function allowing calls to one or more internal units identified by the same call address as used
by the external unit.
Selective intercom: function allowing calls to one or more internal units identified by a dedicated call address (see
table B) which is different from the one used by the external unit.
General and selective intercoms CANNOT be used together on the same riser.
Take note of the S2, S1 setting and restore it when programming is complete
Selective intercom addresses
You must set the intercom address on all the risers internal units.
You can assign the same intercom address to a maximum of 3 internal units.
For group calls, select the desired intercom codes simultaneously (max. 3).

Related product manuals