9. Service and maintenance
54
9.14 Inspection intervals for pressure
vessels and electrical installations
Pressure vessels
As per the requirements of the 2014/68/EU Pressure
Equipment Directive, a qualified person must inspect
the pressure vessel from inside every five years.
As per the requirements of the 2014/68/EU Pressure
Equipment Directive, an appointed body must perform a
strength test on the pressure vessel after ten years.
Electrical installation
The electrical installation must be inspected by a
qualified electrician after four years and also each time
work has been performed on it.
Should stricter inspection intervals apply in your
country, these must be observed.
9.15 Maintenance information and
lubricant recommendations for
stationary compressors
Lubricant recommendations
Please note that proper lubrication will considerably
increase the service life of your compressor unit.
According to regulations relating to the prevention of
accidents, use lubricants the properties of which meet
the requirements of the operating conditions on site.
Do not mix lubricating oils of different makes. When
changing over to a new oil type, drain the old oil
completely from the system.
If final compression temperatures of more than 90 °C
(195 °F) occur continually, the oil change intervals given
in section 9.3 (maintenance schedule) are halved.
The oil change intervals should be calculated more
accurately in accordance with the actual operating
conditions by analyzing the oil.
Use the following oil type:
European version
CompAir „4000“
USA-version:
a) CompLube 4000
b) CompLube 4000FG Food Grade (Optional)
c) CompLube 8000 (Optional)
d) CompLube 8000H1 (Optional)
For further information, please contact your local
CompAir Distributor or Gardner Denver-USA at
(937) 498-2500.
CANADA-Version:
a) CS6000XL
b) CSS20 Food Grade (Optional)
For further information, please contact your local
CompAir Distributor or Gardner Denver-Canada at
(905) 847-0688.