Table 2-12. Audio Test Error Codes
===========================================================================
Error
Code Description Recommended Action
===========================================================================
3206 - xx Audio System Internal Replace the audio board and retest.
Error
===========================================================================
Table 2-13. Pointing Device Interface Test Error Codes
===========================================================================
Error
Code Description Recommended Action
===========================================================================
8601 - xx Mouse test failed The following steps apply to 8601 - xx
and 8602 - xx:
8602 - xx Interface test failed
1. Replace with a working pointing
device and retest.
2. Replace pointing device interface
board and retest (if applicable).
3. Replace the system board and retest.
===========================================================================
Table 2-14. CD-ROM Test Error Codes
===========================================================================
Error
Code Description Recommended Action
===========================================================================
3301 - xx CD-ROM drive read The following steps apply to error
test failed codes 3301 - xx through 3305 - xx and
6600 - xx through 6623 - xx:
3305 - xx CD-ROM drive seek
test failed 1. Replace the CD and retest.
2. Check the jumper settings on the
6600 - xx ID test failed adapter board.
3. Verify that the speakers are
6605 - xx Read test failed connected.
4. Check and/or replace the power and
6608 - xx Controller test signal cables and retest.
failed 5. Replace the CD-ROM drive and retest.
6623 - xx Random read test
failed
===========================================================================
The SCSI error codes are written in the format AABB-CC and can be
determined by looking up the respective parts of the code in the three
corresponding tables numbered 2-15A, 2-15B, and 2-15C shown below. AA
(Table 2-15A) identifies the drive type being tested. BB (Table 2-15B)
identifies the type of test. CC (Table 2-15C) identifies the exact error
received.
For example, if you received a diagnostic error code of 6523-05, you would
look at Table 2-15A to identify the meaning of the first two numbers, 65.
This indicates a hard drive problem. The second set of two numbers, 23,
refers to a random read, as shown in Table 2-15B. The last two numbers,