05, indicate a seek failure, as listed in Table 2-15C. When you combine
this information, you know that the diagnostics program was testing the
random-read functioning of the hard drive and received a seek failure.
The device is faulty and must be replaced.
Table 2-15A. SCSI Device Names
===========================================================================
65XX - XX Hard Drive
66XX - XX CD-ROM Drive
67XX - XX Tape Drive
===========================================================================
Table 2-15B. SCSI Test Names
===========================================================================
XX00 - XX ID
XX03 - XX Power Check
XX05 - XX Read
XX06 - XX SA/Media
XX08 - XX Controller
XX23 - XX Random Read
XX28 - XX Media load/unload
===========================================================================
Table 2-15C. SCSI Test Error Codes
===========================================================================
Error
Code Description Recommended Action
===========================================================================
XXXX - 02 Drive not installed Check cable connections.
---------------------------------------------------------------------------
XXXX - 03 Media not in drive Install DATA CD/write-enabled tape in
drive.
---------------------------------------------------------------------------
XXXX - 05 Seek failure Replace the indicated device.
XXXX - 06 Drive timed out
XXXX - 07 Drive busy
XXXX - 08 Drive already reserved
XXXX - 09 Unknown
XXXX - 10 Unknown
XXXX - 11 Media soft error
XXXX - 12 Drive not ready
XXXX - 13 Media error