PM1323
6-9 TROUBLESHOOTING
WARNING
READ SAFETY BLOCKS at beginning of manual before
proceeding.
TROUBLE SOLUTION
Check control settings.
Check and adjust engine speed.
Check weld connections.
Check control settings.
Check and replace F1 if necessary.
Contact your authorized sevice center for clean slip rings,
and install new brushes, if necessary.
NO
WELD
OUTPUT.
Check control settings.
Use dry electrodes
Clean & tighten all weld connections on welder generator.
Tighten all connection on range and selector switches
Check and adjust engine speed.
ERRATIC
WELD
OUTPUT
HIGH OR LOW
WELD OUTPUT
Clean & tighten all weld connections on welder generator.
Contact your authorized sevice center for clean slip rings,
and install new brushes, if necessary.
TABLE 6-1 WELDING TROUBLE
TABLE 6-2 AUXILIARY POWER TROUBLE.
SOLUTIONTROUBLE
Check and replace F1 if necessary.
Contact your authorized sevice center for clean slip rings,
and install new brushes, if necessary.
Check and adjust engine speed.
Contact your authorized sevice center for clean slip rings,
and install new brushes, if necessary.
Check and adjust engine speed.
Check all connection on receptacles
NO AUXILIARY
POWER OUTPUT.
ERRATIC
POWER
OUTPUT.
LOW OR HIGH POWER OUTPUT.
Increase fine adjustment control R1 if low power output.
Check CB1-3 BREAKERS.