12 Technical Data
12.1 Transmitter General
Instrument name, type: Statox 506 Transmitter Type 5376
Manufacturer: COMPUR Monitors GmbH & Co. KG, D-81539 München
Measuring principle: electrochemical
Operation temperature: -30°C to +60°C ambient air temperature
Storage temperature: -30°C to +60°C
Humidity: 0 to 99% r.F. (non condensing)
Pressure: 900 to 1100 hPa
Accuracy at calibration concentration: ± 10%
Power supply: 24 VDC (12 -28 VDC)
Connections: 2- or 3-wire operation
Terminal width: 0.25 2.5 mm² (AWG 24 12)
Output: 0 - 22 mA, max. load 545 Ohm
Service mode: 2 or 4 mA adjustable
System failure: 0 mA 3-wire operation, 2 mA 2-wire operation
Overrange: 22 mA
Display: 8-digits, 14 segments
Dimensions (HxWxD): 180 x 111 x 81 mm
Weight: ca. 1200 g
Housing material: Cast aluminium, enameled / stainless steel
Ingress protection EN 60529: IP 66
Installation: Sensor downwards
EMV: EN 50270
ATEX marking: Ex ib IIB T4 Gb
Application: II 2G
Approval: BVS 18 ATEX E 066 X / N2 *
)
Power supply U
i
:
max. 28 VDC
Current I
i
: max. 93 mA
Power P
i
: max. 650 mW
Internal capacity C
i
: 24 nF
Internal Inductivity L
i
: neglectable
Functional safety: SIL 2 compliant with IEC 61508
*
)
X- Marking: requires potential equalization along the intrinsically safe loop.
12.2 Sensor Data
Statox 506 sensors are solely electrochemical 2- or 3-electrode sensors.
The listed parameters are typical data measured at 20°C, 50% r.F. and 1013 mbar.
Response time has been measured with Statox 505/506 gas adapter at a flow of 20 l/h.