6 - 2 0 l Tr o u b l e s h oo t in g
Problem
Setback RTD Integrity - The
control can not sense the set-
back RTD.
Possible cause
The connection in the electrical enclosure
for the hopper RTD is loose.
The connection of the RTD plug on the
control board is loose.
The setback RTD has failed.
The control board has failed.
Solution
Check the RTD plug connection and
tighten if needed.
Check the plug connection and tighten if
needed.
Replace the setback RTD.
Replace the control board.
Pa ss i v e Ala r ms
If an alarm occurs, a red dialog box is displayed on the dryers touch screen
control. The dryer continues to operate, but this problem could prevent correct
drying of your material. The dialog box will indicate whether the alarm is a
shut down alarm or a passive alarm.
NOTE: This alarm is option-
al. For more information on
updating your dryer to uti-
lize this and other features,
contact Conair.
Conair’s Instant
Access 24/7 Parts and
Service number is
800-458-1960.
Outside the U.S., dial
814-437-6861.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Conair Carousel Plus W Series and is the answer not in the manual?

Conair Carousel Plus W Series Specifications

General IconGeneral
BrandConair
ModelCarousel Plus W Series
CategoryDryer
LanguageEnglish

Related product manuals