C - 2 l A p p en d ix C
DCͲTModbusTCP/IPReadOnlyData
V02 02/3/2014
Device ModbusStart ModbusEnd
DryerStandAlone 40100 40199
Data Description Type Access RangeMax RangeMin
DeliveryAirDewpoint Real ReadOnl
Ͳ40 40
RegenTempActiveSetpoint Real ReadOnl
70 450
RegenTempWheelInlet Real ReadOnl
RegenTempWheelOutlet Real ReadOnl
ReturnAirTempDryerInlet Real ReadOnl
ControlPanelTemp Real ReadOnl
DryerTotalRunHours Real ReadOnl
DeliveryAirTempSetpoint Real ReadOnl
DeliveryAirTemp Real ReadOnl
DeliveryAirHeaterOn% Real ReadOnl
0 100
HopperOutletTemp Real ReadOnl
DeliveryAirTempSetpoint(InSetback) Real ReadOnl
HopperOutletTempSetpoint(SetbackActivation
ProcessProtectionTemp Real ReadOnl
PassiveAlarmStatus1 Integer ReadOnl
Bit0 DeliveryAirTemperatureDeviation Bit ReadOnl
Bit1 DryerProcessLowTemperature Bit ReadOnl
Bit2 DryerRegenTemperatureDeviation Bit ReadOnl
Bit3 DryerRegenTemperatureLow Bit ReadOnl
Bit4 DryerRegenTemperatureHigh Bit ReadOnl
Bit5 DryerRegenTemperatureLoopBreak Bit ReadOnl
Bit6 DryerReturnAirMidͲHighTemperature Bit ReadOnl
Bit7 DryerAfterCoolerLoopBreak Bit ReadOnl
Bit8 DryerDeliveryAirDewpointAlarm Bit ReadOnl
Bit9 DryerProcessFilterClogged Bit ReadOnl
Bit12 DryingMonitorLowTemperature Bit ReadOnl
Bit13 DryingMonitorTemperatureNotMet Bit ReadOnl
PassiveAlarmStatus2 Integer ReadOnl
Bit4 DryerRegenBlowerOverload(ShutdownAlarm) Bit ReadOnl
Bit5 DryerWheelRotationFail Bit ReadOnl
Bit6 DryerDewpointHighDeviation Bit ReadOnl
Bit7 DryerDewpointLowDeviation Bit ReadOnl
Bit10 DryerDryingMonitorHigh Bit ReadOnl
40120
40122
40124
40126
Address
40141
40140
40100
40102
40104
40106
40108
40110
40112
40114
40116
40118
RangesareinEnglishUnitswhennot
labeled