4 - 2 0 l Op e ra ti o n
C o n t r o l Fun c ti o n D es c ri p ti o ns - R W
C o n f i g u r a ti o n
( c o n ti n ue d )
Hopper Setpoint Settings screen
To access the Hopper Setpoint Settings screen:
1 Press the Magnifying Glass (zoom) button associated with the hopper on the
Individual Hopper screen.
The Hopper Settings Screen allows the user to establish the setpoints for the Delivery Air,
the Setback, the Hopper Outlet Temperature, and to enable/disable the Setback feature.
These setpoints can be adjusted for each hopper in your drying system (if equipped with
setback).
Temperature Setback explained:
The purpose of Temperature Setback is to save on delilvery air heat (energy) and to mini-
mize resin degradation due to overheating the material.
Temperature Setback works by monitoring the air temperature at the top of the hopper. The
setback features drops the delivery air temperature if the air temperature at the top of the
hopper gets too high. This saves energy and keeps the material from overheating.
NOTE: Depending on which options
your dryer has been configured
with, and whether or not you have
the DM3-e Drying Monitor enabled,
your screens and icons may appear
different. For example, if your
ResinWorks system is DM3-e
equipped, your hoppers will display
as Drying Monitor hoppers.
NOTE: Set points boxes are white
with heavy black borders. Set
points can be changed, if the user
has logged in at the proper security
level, by pressing the set point
boxes. This will launch a pop-up
keypad window that can be used to
change the set point.
See Operation
section entitled, How to Navigate
the Control Screens.
After the new
set point value has been entered,
press the "Enter" key to lock in the
new set point.
NOTE: See the Appendix of this
User Guide for more information
about using the DM3-e Drying
Monitor.
(continued)
Ready to Run
350
280
2
00
NOTE: Setback must be inistalled and enabled at each HTC in a central drying system.
NOTE: High temperature at the top of the hopper could be the result of dried resin not leaving the hopper as it
should, or fresh resin not entering the hopper as it should. Check the conveying system to make sure that
material is entering and exiting the hopper when it should be.