Edition 04/2010 - CC100
NOTES TECHNIQUES - TECHNICAL DOCUMENTS - page 23
SACOME, Document CONFIDENTIEL,
Ne peut être reproduit ni communiqué sans notre accord préalable.
SACOME, CONFIDENTIAL Document,
it is forbidden to duplicate or communicate this document without previous authorization.
19.1.3. Programming of boiler temperature:
The factory temperature setting is adjusted at 117 °C by default.
The temperature can be set between 105 ° C and 124 ° C, to change the setting proceed as
follows:
a) Turn off the machine.
b) Keep pressing the keys "P3 Gr1 +" P4 Gr1 + "P5 Gr1" and turn on the machine.
The technician can view the temperature by flashing the LEDs “L1 Gr1 " L2 Gr1" "L3 Gr1. It
corresponds to the hundreds, tens and units of the temperature (in ° C or in °F). There is a pause
of 2 seconds between 2 visualizations of temperature to allow the user to make a new recording. If
a value is zero, the corresponding LED does not light.
Example of reading for a temperature at 115 ° C:
Reading the number of flashes of the hundred: 1
Reading the number of flashes of the ten: 1
Reading the number of flashes the unit: 5
To change the set point you have to press the key "P1Gr1" to decrease (- key) or "P2 Gr1" to
increase (+ key). For each action on the key the value is changed by 1 unit. During the changes,
the LEDs remain off.
If the electronic does not detect any change in the setting for more than one second, the
sequence of displaying the temperature start again for a new visualization.
To exit the programming phase, turn off and on again the machine.
19.1.4. Programming for using the pump for filling boiler:
If the machine is connected to a water network, it is not necessary to use the pump for filling the
boiler (minimum inlet pressure 1.5bar).
If the machine is connected to a water tank, to fill the boiler you have to activate the pump.
The machine is configured by default "without pump" to fill the boiler.
If the technician wants to use the pump to fill the boiler, it must proceed as follows:
_ Settings of the machine to use the pump to fill up the boiler
a) Turn off the machine.
b) Keep pressing the keys "P1 Gr1 +" P4 Gr1 "and turn on the machine.
c) When the LEDs “L1 Gr1 + "L4 Gr1" light, turn off the machine again.
d) Wait a few seconds then turn on the machine.
If the technician wants to eliminate the use of the pump when filling boiler, you must proceed as
follows:
_ Settings of the machine to suppress the pump to fill up the boiler
a) Turn off the machine.
b) Keep pressing the keys "P2 Gr1 +" P4 Gr1 " and turn on the machine.
c) When the LED "L2 Gr1 +" L4 Gr1 "light, turn off the machine again.
d) Wait a few seconds and then turn on the machine.