212-M-V2.1
Specification 9
Construction
Enclosure Material: ABS/Polycarbonate.
Colour: Light beige.
Protection: Sealed to IP67 (Nema 4X).
Mounting: Wall mounting or panel mounting.
Dimensions: 152mm (6.0") wide x 98mm (3.9") high x
43mm (1.7") deep.
Alarm Output (not available if 4-20mA Output Option is installed)
Type: Two solid state opto-isolated relays which
will sink up to 250mA. 30V dc maximum.
Function: High and low alarms
individually programmable as unsigned
values, for volumetric flow rate, energy
flow rate, feed temperature, return
temperature or temperature difference.
4-20mA Output Option
Function: Volumetric flowrate, energy flowrate,
feed temperature, return temperature
or temperature difference.
Output Range: 2.0mA to 22.0mA.
Linearity: 0.02% of span.
Accuracy: 0.1% of span.
Response Time: 0.5 seconds to 99%.
Maximum Output: Vdc -6V.