Service manual OEB/OES/OGB/OGS
5_00e Troubleshooting list_L 12/27 2013-01-30
E
T
O
E
B
O
E
S
O
G
B
O
G
S
Error-
message
Error description possible cause or remedy
Control defective or faulty cable
Air inlet valve clogged or blocked
E65
ID81
Cleaning termination
by general error*
EMV-error CM
Conducted interference CM during cleaning
* = at the start of the automatic cleaning program (Since software version 1.3.0.20)
**= during the automatic cleaning (Since software version 1.3.0.20)
E81.xxx Program memory
error
If the working parameter of a multi-step program are not
between min. and max. values.
After saving a cooking plan in the cookbook the
temperature display is changed from °C to °Fahrenheit.
E82.xxx WP error
(operating parameter
error).
Until incl. V5.0 exist,
then E97.xxx group
error.
If the working parameter of the cooking program are not
between min. and max. values.
Invalid data stored in the cookbook
E83.xxx
ID47
Algo error (invalid
cooking algorithm)
Incompatible software between operating module and
control module.
ID48
No data valid at the
IDM Modul
IDM module is defective
Checksum faulty -> take Unit 10 sec. from the power and
restart
E96.xxx
ID30
Connection faulty
between control
module and operating
module
Moisture on the electronic boards
Interface cable between control module and operating
module interrupted
Plug on the control module or operating loose
Communication between CM and OM disturbed briefly ->
take Unit 10 sec. from the power and restart
Wrong software on the CM (at ET)
CM is defect (at ET)
ID30
Connection faulty
between control
module and operating
module
Cable between ET-OM and CM defect or not properly
contactable -> control.
CM software not suitable to ET-OM software -> over-
setting service-io update the CM
E97.xxx Group error
The error appears when a detailed report cannot be
produced.
E99.xxx
ID31
Communication
Interface to the CM
cannot be opened
Initialization fault of the COM port -> take Unit 10 sec.
from the power and restart
E99.9
ID32
General Initialization
error
Take Unit 10 sec. from the power and restart