Service manual OEB/OES/OGB/OGS
5_00e Troubleshooting list_L 13/27 2013-01-30
E
T
O
E
B
O
E
S
O
G
B
O
G
S
Error-
message
Error description possible cause or remedy
Not
enough
cleaner
pressure
Too little flow pressure
on the pressure switch
S2 (after 40 secs. still
below 0.1 bar)
Cleaner level/nozzle flushing agent level in the canister
too low
Wrong pressure switch installed: (80, 120, 150,
200mbar)
Piping in the pump box is kinked
Suction hose not in the cleaner fluid / nozzle flushing
agent
Rotor nozzle worn or defective -> loses too much fluid in
the middle
Cleaner nozzle behind suction plate is loose or missing
Piping in the pump box leaking
Rinse pump / Cleaner pump without supply voltage
Rinse pump / Cleaner pump overheated
Rinse pump / Cleaner pump defective
Fatal
IDM error
ID48
No viable record in the
IDM module and
control module
Operating of the unit is
no longer possible.
When switching on and booting the appliance controller
finds no viable record either in the control module itself
or in the IDM
a) due to overvoltage record in the IDM was
destroyed
b) IDM module defective
c) contact problems of the X10 plug
IDM error IDM module error
Unit can be used
unrestricted.
When switching on and booting the appliance controller
finds no viable record in the IDM.
If there is a viable record in the CM itself, there is an
attempt to transfer this to the IDM. If this works, the error
disappears, if not, the error always appears briefly when
switching on
fit new IDM
Short cut:
CM = Control modul OM = operating modul
SG = Steam generator FC = Frequency converter
GM = Gas modul FA = Flame Controller
ET = easyTOUCH