Service manual OEB/OES/OGB/OGS
KD / 31.03.2009 5_00d_Fehlersuchliste_h_En.doc
Page 13 / 21
OEB
OES
OGB
OGS
Defect
Possible cause or remedy
5.2 General
5.2.1 No interior lighting, however
appliance fully functioning
Light bulb of interior light defective
Microfuse defective
5.2.2 After starting a programme
appliance not functioning
Doors not closed
Magnet on the door is not in the right
position
Solenoid switch in the door stud defective
Check setup of the appliance (examine floor
model for warping)
Appliance is set to dummy version Set to
normal version: c12=305; c13=999
5.2.3 Not enough water,
however no display of the
insufficient water symbol in the
display of the electronics, boiling
dry of the immersion heaters
Due to insufficient rinsing of the steam
generator foaming water
Water level sensor has short circuit to earth
due to contamination/calcium in the steam
generator
Contact problem on level sensor (possibly
short circuit to earth)
Opening in the area in the steam generator
touching the water closed by calcium
deposits
5.2.4 Water runs underneath the
floor of the appliance from the
condenser overflow
Building’s drainage pipe blocked
Building’s tundish funnel blocked
5.2.5 Water inside the oven
Dirt filter in the outflow of the working
chamber contaminated
Condenser blocked (dirt filter not present)
Demoisturisation tray dirty
5.2.6 No temperature increase
in convection mode
Safety temperature limiter B7 has tripped
Heater contactors do not pull in
a) Contact problem on heater terminals
b) Heater contactor defective
Hot air heaters defective
5.2.7 Uneven browning
Suction plate not correctly fitted
Heat produced by the hot air heater is too
low
Application error: e. g. not sufficiently pre-
heated
Load not centrally placed in the oven