Service manual OEB/OES/OGB/OGS
KD / 31.03.2009 5_00d_Fehlersuchliste_h_En.doc
Page 14 / 21
OEB
OES
OGB
OGS
Defect
Possible cause or remedy
5.2.8 Water drips out of the front
area of the appliance floor in
table-top models
Seak between inner and outer housing is
worn or missing Check seal groove for
door seal
Channel seal between appliance drip tray
and housing is missing
Door seal worn
5.2.9 Too dry or too wet in
programmes with steam
Pressure balance valve in oven ceiling open
Check and adjust, if necessary, clean
Pressure balance valve in oven ceiling
blocked Clean with hand shower
Solenoid valves are not closing properly
Bypass sensor greased up / bypass
opening blocked (not with OES 6.06)
Demoisturisation activated
5.3 Steam generator
5.3.1 Steam generator is still not
ready to operate after 5 mins
Check polarity of the B4 sensor connection
(green/white)
Overfilling of the steam generator
Heater contactors do not pull in
a) Contact problem on terminals
b) Heater contactor defective
Immersion heater / heat exchanger in the
steam generator calcified
Immersion heater defective
5.3.2 Uncontrolled steam supply
in stop mode, and moisture in
the convection programme
Check polarity of the B4 sensor connection
(green/white)
Steam generator or pre-heating sensor
calcified see 4.4 Decalcifying the
CONVOTHERM
Pre-heating temperature set too high in c01
Electronics’ temperature detection defective
( Replace control module CM)
5.3.3 Steam generator is no long
switching off
Check polarity of the B5 sensor connection
(green/white)
Bypass pipe has come loose
Bypass pipe T-piece and B5 blocked or
greased up
Constant water supply in the condenser
Electronics service programme c 05 on
permanent steaming
Short circuit of the B5 sensor wiring