Service manual OEB/OES/OGB/OGS
KD / 31.03.2009 5_00d_Fehlersuchliste_h_En.doc
Page 15 / 21
OEB
OES
OGB
OGS
Defect
Possible cause or remedy
5.3.4 No water supply in the
steam generator
Water supply pipe closed
Injection part in non-return flow device
contaminated
Dirt filter in hose fitting contaminated
Inlet filter in the solenoid valve
contaminated
Solenoid valve Y3 is not opening
a) Solenoid valve defective
b) Contact problem on the plug
Contact problem on level sensor (short
circuit to earth)
5.3.5 No steam supply in the
programmes with steam and hot
air
Short circuit of the B5 sensor wiring
Heater contactors do not pull in
Immersion heaters in the SG defective
No water in the SG
5.3.6 Water or foam sprays out
of the steam outlet aperture in
the inner chamber
Steam generator overfilled
Cleaning agent or decalcifier residues are in
the SG Flush out thoroughly several
times
5.3.7 Constant water supply in
the condenser
Solenoid valve Y3 is not closing
a) Solenoid valve contaminated (hangs)
b) Solenoid valve defective
c) Water pressure too low (min. 2 bar)
Water level sensor is not switching
Contact problem on water level sensor or on
clamp connection
Electronics - fixing pin (earth connection)
loose
Conductance of the water too low
Insulating layer on water level sensor
5.3.8 Water sprays out of air
outlet pipe (roof of appliance)
Bypass pipe dirty, blocked or has a water
pocket (sags)
B5 sensor (steam measuring sensor)
greased up
Exhaust pipe blocked
Steam generator blocked in the area of the
water supply pipe