Service manual OEB/OES/OGB/OGS
KD / 31.03.2009 5_00d_Fehlersuchliste_h_En.doc
Page 17 / 21
OEB
OES
OGB
OGS
Defect
Possible cause or remedy
5.6 Electronics (see also General)
5.6.1 Displayed oven
temperature does not agree with
the actual oven temperature
Short circuit of the B6 sensor wiring
Check polarity of the B6 sensor
(green/white)
5.6.2 Time or temperature value
set changes up or down all by
itself after being set
Movement of the selector dial was not
correctly recognised by the electronics
Move selector dial briefly in same direction
Photosensor and receiver have no contact
with one another Align position
5.6.3 Temperature displays are
not correct: the higher the
temperature on the sensor, the
lower the temperature value
displayed
Polarity incorrect Check the connection
leads of the sensor in question (green and
white wires must not be reversed)
-
-
5.6.4 Electronics can be
operated normally, but appliance
is not working
Appliance is set to dummy version
Main contactor defective
see also point 5.5
5.6.5 Software hangs due to
buttons having been pressed
quickly several times
Re-install software by pressing the On / Off
button for 5 secs. or by disconnecting from
the power supply for 10 secs.
5.7 Safety temperature limiter hot air heater (B7)
5.7.1 Safety temperature limiter
(B7) has tripped.
Inner chamber temperature was over 300 °C
Heater contactor is burnt together
Replace contactor
Check polarity of the B6 sensor
(green/white)
5.7.2 Safety temperature limiter
B7 is reacting too early.
B7 defective

Table of Contents