Service manual OEB/OES/OGB/OGS
Test of the outputs
i
Information:
The controller offers the possibility of activating various outputs and various
functions via the service numbers d04 - d24. As part of this these outputs can be
checked and defects identified.
Safety:
Page 5 / 6
Repeated triggering of certain actuators shortly after one another may
permanently damage them!!!
Service no.:
Description
Plug
Pin
Comments
d04
Self-test of the operating module
d05
Testing of the steam generator heater
1
X12
4
With OES / OGS open Y4 = steam
generation
d06
Testing of the steam generator heater
2
X11 8
d07
Testing of the hot air heater 1
X12 3
d08
Testing of the hot air heater 2
X11 7
d09
Testing of the light
X12 2
d10
Testing of the auxiliary fan
X10 1+2
d11
Testing of the main contactor
X13 2
d12
Testing of the SV store condenser
X12 5
d13
Testing of the SV storing SG
X12 7
d14
Testing of the pump SG draining
X13 1
d15
Testing of the SV demoisturising
X12 6
d16
Testing of the PFC energy opt.
X13 9+10
Demoisturisation flap in the 6.06
d17
Testing of the motor fast clockwise
X11 4+5
Not with Single Phase
d18
Testing of the motor slow clockwise
X11 4+6
Not with Single Phase
d19
Testing of the motor fast anti-
clockwise
X11 3+5
Not with Single Phase
d20
Testing of the motor slow anti-
clockwise
X11 3+6
Not with Single Phase
d21
Testing of the water nozzles
X13 3
d22
Testing of the nozzle flushing
X13 4
d23
Testing of the cleaning agent pump
X13 6
d24
Testing of the reset automatic ignition
X14 3
Not with Single Phase
AS/11-2011 3_01e Customer service - Service programme_f