Service manual OEB/OES/OGB/OGS
Page 4 / 6
Service no.:
Description
Plug
Pin
OES 6.06
OEB
OES
OGB
OGS
Minimum
settin
g
Maximum
settin
g
Default value
Comments
Unit
c14 Option1
- - -
Only CONVOTHERM int.
c15 Option2
- - -
Only CONVOTHERM int.
c16 Restart hours
0 48 0 h
c17 Restart mins.
0 59 15
minut
e
c18 Ignition attempts
1 5 2
c19 PIN
0 999 001
c20 Sterilising
0 1 0
c21 Shine by level
1 4 4
c22 Cleaning agent dosing
3 15 5 s
c23 Running time right
20 250 120 s
Only CONVOTHERM int.
c24 Running time left
20 250 120 s
Only CONVOTHERM int.
c25 Slow-down time
0 250 15 s
Only CONVOTHERM int.
c26 HA Nmin (HA=Hot air)
1000
9000
1000
RPM
Only CONVOTHERM int.
c27 HA Nmax
1000
9000
7000
RPM
Only CONVOTHERM int.
c28 HA Nstart
1000
9000
3000
RPM
Only CONVOTHERM int.
c29 HA safety time
0 255 6 s
Only CONVOTHERM int.
c30 HA run up
0 255 0 s
Only CONVOTHERM int.
c31 HA1 Actual speed
- - -
RPM
Read value only
c32 HA1 PWM
- - - %
Only CONVOTHERM int.
c33 HA1 (HA1=Hot air1)
- - -
HFAR*²
c34 HA2 Actual speed
- - -
Read value only
c35 HA2 PWM
- - -
Only CONVOTHERM int.
c36 HA2 (HA2=Hot air2)
- - -
HFAR*²
c37 SG Nmin fan
1000
9000
1000
RPM
Only CONVOTHERM int.
c38 SG Nmax fan
1000
9000
6000
RPM
Only CONVOTHERM int.
c39 SG Nstart fan
1000
9000
3000
RPM
Only CONVOTHERM int.
c40 SG safety time
0 255 10 s
Only CONVOTHERM int.
c41 SG run up
0 255 0 s
Only CONVOTHERM int.
c42 SG actual speed fan
- - -
RPM
Read value only
c43 SG PWM
- - - %
Only CONVOTHERM
int.
c44 SG (SG=Steam generator)
- - -
HFAR*²
d01 Delete error
*
d02 Remove button lock
*
d03 Delete all progs.
*
d04 Self-test of the operating
module
*
= Activate using the right-hand scroll button (inversely shown), then select using selector dial "1"
and exit again using left-hand scroll button and thus save.
*² = HFAR
- H = Heat demand - A = Alarm automatic firing
- F = Valve open (Flame OK) - R = Reset automatic firing
AS/11-2011 3_01e Customer service - Service programme_f

Table of Contents