Possible error messages:
Error
no.
Message in the
display
Description OES
6.06
OEB OES OGB OGS
E01.0 Not enough water Not enough water X X X X X
E02.0 Elec. temp. too high Excessive temp. in the wiring space X X X X X
E03.0 Fan malfunction Fan malfunction X X X X
E03.zzz-
xxx-yyy
Fan malfunction Fan malfunction / Frequency converter error X X
E04.0 Elec. fan malfunction Auxiliary fan malfunction X X X X X
E05.0 No gas No gas or error in the burner system X X
E05.1 No gas No gas at the burner HA1 X X
E05.2 No gas No gas at the burner SG X
E05.3 No gas No gas at the burner HA2 X X
E05.4
E05.4-1
E05.4-2
No gas Start speed at the burner HA1 not reached X X
E05.5
E05.5-1
E05.5-2
No gas Start speed at the burner SG not reached X
E05.6
E05.6-1
E05.6-2
No gas Start speed at the burner HA2 not reached X X
E05.7
E05.7-1
E05.7-2
No gas Full load speed at the burner HA1 not reached X X
E05.8
E05.8-1
E05.8-2
No gas Full load speed at the burner SG not reached X
E05.9
E05.9-1
E05.9-2
No gas Full load speed at the burner HA2 not reached X X