Service manual OEB/OES/OGB/OGS
AS/11-2011 3_02e Error messages_c
Error Message in the Description OES OEB OES OGB OGS
Page 2 / 2
no. display 6.06
E11.0 Excessive temp. oven Excessive oven temperature X X X X X
E13.0 SG excessive temp. Excessive steam generator temperature (water
foaming)
X X
E15.0 Excessive condenser
temp.
Excessive condenser temperature X X X X X
E16.0 Demoisturisation flap
error
Error demoisturisation X
E21.0 Oven sensor failure Oven sensor failure X X X X X
E22.0 CTS faulty Core temp. sensor failure X X X X X
E23.0 SG sensor failure Steam generator sensor failure X X
E24.0 Bypass sensor failure Bypass sensor failure X X X X
E25.0 Condenser sensor failure
Condenser sensor failure X X X X X
E26.0 STL SG sensor failure STL sensor failure X X
E27.0 Excessive temp. SG
heater
STL excessive temperature X X
E29.0 Earth connection of a
sensor
Earth connection of a thermoelement (defective)
X X X X X
E33.0 SG heater error No temperature increase in the SG can be measured
- steam generator heater defective
X X
E34.0 SG pump error Steam generator pump defective X X
E80.0 ID error Identity error - appliance cannot ascertain
whether it is gas or electric
X X X X
E81.0 Programme memory
error
Stored programme parameters outside valid
range
X X X X X
E82.0 WP error Current programme parameters outside valid
range
X X X X
E83.0 Alg. error Invalid cooking algorithm X X X X X
E89.0 IDM error Identity module defective X X X X
E95.0 Software error Hardware and software are incompatible X X X X
E96.0 Connection defective Communication control module - operating
module not possible
X X X X X
- Fatal IDM error No viable record in the IDM module and control
module
X X X X X
- IDM error IDM module error X X X X X
- Lack of cleaning agent
pressure
Pressure switch of CONVOClean system is not
detecting pressure
X In appliances with
CONVOClean system
X = error possible (depending on size of appliance, hardware and software version)
Cross reference:
You will find more detailed error descriptions in the service manual chapter 5.
“Troubleshooting list and error messages - Electronics”

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Convotherm OEB Series and is the answer not in the manual?

Convotherm OEB Series Specifications

General IconGeneral
BrandConvotherm
ModelOEB Series
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals