Service Handbook OEB/OES/OGB/OGS
3. Spray ventilation area and back side of suction panel with original
CO
NVOTHERM oven cleaner and allow to work for 10 minutes
4. Afterwards thoroughly rinse the ventilation area and suction panel and in gas
units the heat exchanger with the hand shower.
5. After cleaning the suction panel swing back and fasten with the quick lock.
Advice:
To avoid the problem of uneven browning results, the suction panel must be
fastened and locked correctly
Cleaning the water connection filter
B
A water filter is in the water connection to prevent blo
ckage of the nozzles installed
in the unit.
Instructions:
Unscrew both water connections behind on the under
side of the unit.
Remove filter and clean.
Re-assemble in reverse steps.
Switch unit into operation and check for water tightness.
Advice:
B
5011002
For units without a soft water connection, a double connection piece is
available Part No.: 5011002 as a spare part.
Additionally, a micro filter is available and can be installed against heavier
impurities in the water due to sand, lead particles or suspended particles.
AS/11-2011 4_03e_Cleaning the Unit_c
Page 6 / 7