Service Handbook OEB/OES/OGB/OGS
4.3.4 Further cleaning measures
Cleaning hygenic plug-in gaskets
Regularly cleaned (remove grease) hygenic gaskets greatly increases their life-
span.
Instructions:
For heavy build up of dirt or grease, the door gaskets can be pulled out
without tools (begin on the corners) and cleaned. The gaskets must be cool
before hand.
Use only mild, odourless detergents for cleaning (do not use scouring agents
or cleaning methods which attack the surface).
The hygenic plug-in gaskets can also be cleaned in a commercial dishwasher.
Make sure that they are not mechanically damaged.
The dry gaskets can be installed again (starting at the corners) without the use
of tools.
i
Information:
The lifespan of the hygenic plug-in gaskets is extremely dependent on regular
cleaning and removal of grease and the oven cleaner products that are used. A
maximum lifespan is reached when you use only the original CONVOTHERM
cleaning products.
Cleaning ventilation area
Cleaning the ventilation area behind the suction panel must be performed
according to the amount of build up. Observe the safety advice in Chapters 4.3.1
and 4.3.2
Instructions:
1. Unit main power supply must be disconnected with an all-pole isolation switch
and ensured against switching on again! Wait until the fan comes to a full
stop!
2. Loosen the quick lock on the suction panel and swing suction panel out.
AS/11-2011 4_03e_Cleaning the Unit_c
Page 5 / 7