4.6 Automatic Internal ushing
The machine is equipped with two oil bottles (one for the PAG oil and one for POE oil). Due to low compati-
bility between the two kinds of oil, it is strongly suggested to avoid the mixing between the two.
In order to avoid contamination, the Automatic Internal ushing function performs a machine cleaning phase
at the end of each process involving the oils.
This function can be deactivated if sure that only one type of oil is used with the machine (also in case of
recovery!).
IMPORTANT-NOTE: Excluding this function may cause anomalies in the A/C system and could
create hazardous situations for the user (electric shocks on the A/C compressor unit)
At the end of Vessel Charge, A/C Pressure Test, A/C Data-
Base, Full Service, Open Program (only the ones including
“Recovery” and/or “A/C System Charge”), the display shows:
Perform the instruction, then press START key to conrm.
At the end of the process:
Press STOP key to exit.
Join HP/LP couplers
to the stands and
open the valves
Internal flushing
end
Machine ready!
4.5.3 Company data
Turn COOLIUS SELECT to select
COMPANY DATA.
Press ENTER to conrm.
5 lines are available:
1_________ Company name (Workshop)
2_________ Address (road, etc..)
3_________ City
4_________ Phone
5_________ FAX
The above setting is an example only.
NOTE: The ve lines are reported on the service report.
Procedure:
Turn COOLIUS SELECT to select the character.
Press ENTER to conrm.
The character is reported on the rst line (left).
If required, press X key to delete.
It is possible to move in the line by LEFT / RIGHT
Turn COOLIUS SELECT to select the next character.
Press ENTER to conrm.
The character is reported on the rst line.
Press START key to conrm the setting.
The display shows the following line.
Press STOP when the 5 lines are set.
1_________
C
567890 AB DEFGHIJKLM

Table of Contents