25COOLIUS A50
5.2 Full service
1. Press ENTER to go to selection menu (if in Stand-by
mode).
2. Turn COOLIUS SELECT to select “
FULL SERVICE”
3. Press ENTER to conrm.
4. Turn COOLIUS SELECT to set the amount of refrigerant
to be charged into the A/C system.
• Minimum: 50 g.
5. Press ENTER to conrm.
6. Turn COOLIUS SELECT to set
AUTOMATIC / MANUAL / NO
Press ENTER to conrm.
If AUTOMATIC or MANUAL is selected, then the display
shows:
7. Turn COOLIUS SELECT to set
PAG OIL or POE OIL
Press ENTER to conrm.
If AUTOMATIC is selected, then the display shows:
8. Turn COOLIUS SELECT to set oil quantity,
conrm by ENTER,
then set UV quantity and press ENTER to conrm.
9. Turn COOLIUS SELECT to set (usually HP)
HP PORT / LP PORT / HP/LP PORTS
Press ENTER to conrm.
Equipment with printer:
See chapter 4.2 Using the printer
p. 14
10. Press START key to conrm.
The equipment performs all the processes.
• Recovery
• Residual refrigerant check
• Used oil drain process
• Nitrogen Pressure test (if Nitrogen Press.Test AUTO is
set to 1 in MACHINE SET-UP).
• Vacuum, Leak test
• New oil charge
• UV Dye charge
• Refrigerant charge
Full service
Refrigerant g. 500
Oil/UV charge
Automatic
Select Oil Type
PAG Oil
PAG Oil ml. _
UV dye ml. _
Charge A/C system by
HP PORT
Confirm by “START“