EasyManua.ls Logo

COOLIUS A50 - Operational Programs

COOLIUS A50
43 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
COOLIUS A50
5 Programs
5.1 New oil bottle change
NOTE: A/C System can be damaged.
If it is required to change the kind of compressor oil, the A/C machine will require ushing to
prevent cross contamination of oils. This procedure cleans the hoses and pipes prior to new oil
injection.
1. Turn COOLIUS SELECT to select
OTHER SELECTIONS.
Press ENTER to conrm.
2. Turn COOLIUS SELECT to select
NEW OIL BOTTLE CHANGE.
Press ENTER to conrm
3. Turn COOLIUS SELECT to select the bottle that has to
be replaced (PAG oil or POE oil).
Press ENTER to conrm.
4. Replace the oil bottle with the new oil bottle.
Press ENTER to conrm.
5. Perform the instruction.
Press START key to conrm.
6. The machine starts.
If the couplers are not joint to the stand or the coupler
valves are not closed, message:
7. Press START key to conrm.
The machine starts.The process cleans the complete
unit included the service hoses.
At the end:
8. Press STOP key to exit..
The machine is ready.
New oil bottl.change

Select oil type:
PAG oil
Replace oil bottle
with the new oil
bottle for specific
application.
Join HP/LP couplers
to the stand and
open the valves!
Confirm by “START“
Internal flushing
Wait!
Join HP/LP couplers
to the stand and
open the valves!
Confirm by “START“
Internal flushing
end.