36
COOLIUS A50
6.3 Counter reset (UNLOCK CODE required)
NOTE: Change the lter and/or the vacuum pump oil before reset!
NOTE: Only genuine spare parts or their equivalent The use of replacement parts which are not
of equivalent quality may damage the machine!
Go to website www.coolius-ac.com or call the hotline +497940981888188 to get the UNLOCK CODE for
maintenance counter reset..
1. Press ENTER to type the unlock code.
2. By the COOLIUS SELECT enter the UNLOCK CODE.
Once done, conrm by START.
If the UNLOCK CODE is wrong, repeat the procedure.
If the UNLOCK CODE is right, the display shows:
3. Press X key to conrm.
4. Press X key to conrm.
6.4 Filter replacement
ATTENTION! Risk of injury from leaking refrigerant.
Contact with the refrigerant can cause blindness and other physical injury to
the user!
Always use goggles and gloves!
1. Before dismounting the lter, start a recovery process to re-
duce the internal pressure!
ATTENTION! Risk of injury from electric shock.
Before working on the machine, always disconnect the
plug from the power supply.
The maintenance of the lter can be performed by the inspection
hole placed on the back side of the equipment.
2. By 38 mm
2
wrench unscrew the lter
1
.
NOTE! Disposal in according to local directives!
3. Lubricate and place correctly the new O-rings.
4. Assembly the new lter.
A*******
A
34567890 BCDEFGHIJK
Counter reset.
Confirm by “X”
min. ///
Counter reset.
Confirm again!
g. 009 Filter replacement
2
1

Table of Contents