31COOLIUS A50
3. Enter CAR DATA, then the display shows:
4. Press START to conrm.
The nitrogen valve lls the A/C System.
When the pressure is stable, the machine checks
possible leaks for the time set.
At the end, the exhaust nitrogen valve empties the A/C
System.
Process end.
MESSAGE: If charging pressure is too low
(below the minimum allowed threshold).
Press STOP to exit.
MESSAGE: If during the test a leak is detected:
Press STOP to exit.
Please connect
nitrogen bottle
to press. test
inlet port
Nitrogen Press.Test
in process
Pressure mb. 6500
Nitrogen Press.Test
in process
Time sec. 120
Pressure mb. 6500
Nitrogen Press.Test
in process
Pressure mb. 6500
Nitrogen Press.Test
OK!
Not enough
pressure to test the
A/C system!
Leakage in the
A/C system
under test.