Xenus XSL User Guide Quick Setup with CME 2
Copley Controls Corp. 101
5.9.2: PWM Input
For more information, see PWM Input (p. 27).
5.9.2.1 C
lick PWM Command (
)
to open the PWM Command screen.
5.9.2.2 Set the input options described below.
Option Description
Scaling Current mode: output current at 100% duty cycle.
Range: 0 to 10,000,000 A. Default: Peak Current value.
Velocity mode: output velocity at 100% duty cycle.
Range: 0 to 100,000 rpm (mm/sec).
Default: Maximum Velocity value.
PWM Input
Type
One wire 50% or two wire 100% with direction.
Options Invert PWM input: Inverts the PWM logic.
Allow 100% output: Overrides the 100% command safety measure.
See Failsafe Protection from 0 or 100% Duty Cycle Commands (p. 27).
Invert Sign Input: In 100% duty cycle mode, inverts the polarity of the directional input.
5.9.2.3 Click Close.
5.9.2.4 On the Main screen, click Save to Flash ( ).
5.9.2.5 Proceed to Auto Phase (p. 105).