Using CME 2 Xenus XSL User Guide
142 Copley Controls Corp.
6.6: Error Log and Communications Log
6.6.1: Error Log
The amplifier tracks faults and warnings in an internal error/event log stored in the amplifier’s flash
memory.
To view the log click the Error Log tool on the Main screen ( )
OR click Error Log (
) on the Control Panel.
The log has several sections, accessible by clicking on the tabs described below:
Tab Contents
Active Type and description of each active fault and warning. The contents of this tab are
automatically refreshed as new events occur.
History Type, description, and time of occurrence of each fault and most warnings since the log
was last cleared. The contents of this tab are not refreshed automatically as new events
occur. The contents are refreshed only when the tab is displayed or when Refresh is
clicked.
Frequency Type, description, and frequency of each fault and warning that has occurred since the log
was last cleared. The contents are refreshed only when the tab is displayed or when
Refresh is clicked.
CAN
Network
(Under CAN control only.) Status of CAN bus. Lists warnings and errors.
To update the contents of the History or Frequency tabs, click Refresh.
To clear the log if needed, press Clear Log. (Contents cannot be recovered.)
To save the log to a disk file, click the Save to Disk icon (
) on the log screen.
Then navigate to the appropriate folder, enter a File Name for the log, and click Save.