Specifications Xenus XSL User Guide
50 Copley Controls Corp.
3.1: Agency Approvals
CE Compliance:
89/336/EEC Electromagnetic
EN 55011 Compatibility
EN 550082-1
98/37/EC Safety of Machinery
EN 60204-1
UL 508C
3.2: Power Input
Model XSL-230-18
XSL-230-18-R
XSL-230-36
XSL-230-36-R
XSL-230-40
XSL-230-40-R
Mains Voltage 100 - 240 Vac
1 Ø or 3 Ø
Mains Frequency 47 to 63 Hz
Mains Current 15 Arms maximum 20 Arms maximum
Current Inrush
15 A peak at 120 Vac
35 A peak at 240 Vac
Logic Supply Voltage +20 to +32 Vdc
Logic Supply Current 500 mA maximum
3.3: Power Output
Model XSL-230-18
XSL-230-18-R
XSL-230-36
XSL-230-36-R
XSL-230-40
XSL-230-40-R
Peak Current 18 Adc
[12.7 Arms]
36 Adc
[25.5 Arms]
40 Adc
[28.3 Arms]
Peak Current Time 1 Second
Continuous Current* 6 Adc
[4.24 Arms]
12 Adc
[8.5 Arms]
20 Adc
[14.1 Arms]
Efficiency >97% @ 230 Vac and rated continuous current
Output Type 3-phase IGBT inverter
15 kHz center-weighted PWM
space-vector modulation
PWM Ripple Frequency 30 kHz
Minimum Load Inductance 400 uH line-to-line**
NOTE: See Xenus Filter (p. 173).
* Heat sinking and/or forced air cooling required for continuous output power rating
** Consult factory for operation with inductance lower than 400 uH
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com