Xenus XSL User Guide Using CME 2
Copley Controls Corp. 143
6.6.2: Communications Log
The communications log tracks all communications between CME 2 and the amplifier. The log is
maintained in the PC’s RAM. Use the following instructions to manage the tracking and storage of
these serial port messages.
On the Main screen, choose ToolsCommunications Log to open the
Communications Log screen.
Select the logging options described below.
Option Description
Enable Logging When checked, logging is enabled and all communications, with the exception
of status messages, are recorded in the log
Enable Event Status
Logging
When checked, status messages are included in the log.
Filter “Get Variable”
Cmds
When checked, “Get Variable” commands are not added to the log.
To clear the log contents from the PC’s RAM, press Clear.
NOTE: The log is limited to 2000 lines. When it reaches that limit, CME 2 automatically
clears the oldest 1000 lines.
To save the log contents from the PC’s RAM to a disk file, click the Save to Disk icon
( ). When prompted, enter a File name.
Then, click Save to save the log file and close the window
or click Cancel to close the window without saving the log file.