EasyManua.ls Logo

Copley Controls Xenus XSL-230-18 - Prerequisites; 1: Hardware and Equipment

Default Icon
202 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Quick Setup with CME 2 Xenus XSL User Guide
82 Copley Controls Corp.
5.3: Prerequisites
5.3.1: Hardware and Equipment
5.3.1.1 Verify that +24 Vdc power is OFF and AC power is OFF.
5.3.1.2 Verify wiring and connections.
Ensure the following connections are wired according to the guidelines in
Wiring (p. 59).
1
J8 "FDBCK" motor signals
2 J2 "U V W Earth" motor power
3 J7 "CNTRL" control signals
4 J4 "+24 Vdc, BRAKE" required +24 Vdc (power OFF)
5 J5 "RS-232" PC serial link
6 J1 "L1 L2 L3 Earth" line power (power OFF)
5.3.1.3 Secure the motor:
1 Make sure motor is securely fastened.
2 Make sure that no load is connected to the motor.
5.3.1.4 Apply +24 Vdc to the amplifier’s J4 connection.
(Do NOT apply AC voltage to the amplifier at this point.)
Risk of unexpected or uncontrolled motion with CME 2 in CAN mode.
!
DANGER
CME 2 can be used while the amplifier is under CAN control. However, some
extreme changes made with CME 2 could cause unexpected or uncontrolled motion.
Failure to heed this warning can cause equipment damage, injury, or death.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com