Cold Nitro Brew BIB Dispenser Operator’s Manual
© 2017, Cornelius Inc. 21 Publication Number: 621058723OPR
5
REDUCED FOAM HIGHT adjustment:
A. Adjust the regulator control knob slightly (approxi
mately 1/8th of a turn) to the LEFT (counterclockwise).
Only very fine adjustments are required. This reduces
the amount of Nitrogen injected.
B. Open the RIGHT tower dispenser and dispense about
8 oz. of product to drain the line of product at the previ
ous foam setting. Then dispense 12 oz. of product and
confirm the foam head height. Repeat and dispense
another 12 oz. to confirm setting.
C. Repeat step A if a further reduction of foam head
height is required.
6
INCREASED FOAM HIGHT adjustment:
A. Adjust the regulator control knob slightly (approxi
mately 1/8th of a turn) to the RIGHT (clockwise). Only
very fine adjustments are required. This increases the
amount of Nitrogen injected.
B. Open the RIGHT tower dispenser and dispense about
8 oz. of product to drain the line of product at the previ
ous foam setting. Then dispense 12 oz. of product and
confirm the foam head height. Repeat and dispense
another 12 oz. to confirm setting.
C. Repeat step A if a further increase of foam head height
is required.
7 Reinstall the regulator access cover.