Cold Nitro Brew BIB Dispenser Operator’s Manual
Publication Number: 621058723OPR 20 © 2017, Cornelius Inc.
CHANGING COFFEE TYPES
In some cases the type of coffee used in the CNB BIB unit may require an adjustment of the
height of the foam head for proper presentation. If this adjustment is required, it should be
performed by a manager or technician who is trained in the operation of the CNB BIB unit.
Unit Foam Head Height Adjustment
NOTE: Follow all previous INSTALLATION and CLEANING/SANITATION section processes
before continuing with this section.
Once the equipment has been installed, cleaned, and sanitized, perform the procedure in
Table 6 to adjust the foam head height on the CNB BIB unit.
Table 6.
Step Action
1
Make sure the Nitrogen tank is open or the nitrogen gener
ator is turned on.
The primary side gauge should be between 500 and 2500
PSI and the secondary gauge should between 60 and 80
PSI.
2 Open the cabinet door.
3
Inside the cabinet, ensure that the Nitrogen inlet valve is
turned to the “ON” position.
4
A. Open/remove Nitrogen secondary regulator access
cover.
B. Locate the secondary Nitrogen regulator.
Adjust only the regulator shown.