TROUBLESHOOTING FLAKERS
Trouble Probable Cause Remedy
1. Unit will not run On-off switch in
off position.
Turn switch to on
Defective on-off
switch.
Check and replace.
Blown fuse. Replace fuse and
check for cause of
blown fuse.
Thermostat set
too warm for
ambient.
Adjust colder.
Power relay
contacts
corroded.
Check and clean.
Defective
thermostat.
Check and replace
Loose electrical
connection
Check wiring
2. Compressor
cycles
intermittently.
Low voltage. Check line voltage
Dirty
condenser.
Clean condenser.
Air circulation
restricted.
Remove restriction.
Defective
condenser fan
motor.
Check and replace.
Defective relay,
overload
protector or
starting
capacitor.
Check and replace.