43 TD 184
Trouble RemedyProbable Cause
2. Compressor
cycles
intermittently.
(contd)
Loose electrical
connection.
Check wiring.
3. Making wet ice. Surrounding air
temperature too
high.
Correct or move
unit.
High water level
in float
reservoir.
Lower water level,
Dirty condenser Clean condenser.
Faulty
compressor
Check and replace
Refrigerant leak Check and repair
O ring leaking
at bottom of
evaporator shell
Check and replace
4. Unit runs but
makes no ice.
Leak in
refrigerant
system
Check and repair
Moisture in
system
Check, dehydrate
and add drier to
system
No water Check water supply
O ring leaking
at bottom of
evaporator shell
Check and replace
O ring
Compressor
not running
Check electrical
5. Water leaks Worn or bad
float valve
Check and replace
Float and arm
assembly stuck
Check and replace