10
ELECTRICAL REQUIREMENTS
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to following these instructions can result in death, fire, or electrical
shock.
Observe all governing codes and ordinances.
Product rating:
Required:
• A 120 V, 60 Hz, AC only, 15 or 20 A electrical supply with a fuse or circuit
breaker.
Recommended:
• A time-delay fuse or time-delay circuit breaker.
• A separate circuit serving only this microwave oven.
This product must be connected to a separate and dedicated supply circuit of
the proper voltage and frequency. Wire size must conform to the
requirements of the National Electrical Code or the prevailing local code for
this kilowatt rating.
The power supply cord and plug should be brought to a separate and
dedicated 15- to 20- ampere branch circuit single grounded outlet. The outlet
box should be located in the cabinet above the microwave oven.
The outlet box and supply circuit should be installed by a qualified electrician
and conform to the National Electrical Code or the prevailing local code.
• A 120 V AC, 60 Hz, 15 A, 1550 W.