3. Compressor restart delay time
1) When the compressor is turne off, it restarts 5 minutes later.
- When the power is supplied for the first time, the compressor starts 5 minutes later.
4. Compressor contrrol temperature and FND display specification
Cold water
temperature
Compressor operation Thermistor resistance value
5°C or lower Stops 17 minutes after sensing 5°C 127.249
KΩ
7.3°C or higher Compressor operates 114.012KΩ
FND indication part
Segment display
SEGMENT ON
13.0
°C or lower
When the cold water
function is selected
(ON all the time)
10.0°C 7.3°C 5.0°C
SEGMENT OFF
When the
cold water
function is of
f
13.0°C 10.0°C 7.3°C
5. Cooling safety shut-off function
1) When the compressor operates continuously for 150 minutes, the compressor is turned off for
5 minutes regardless of the cold water tempersture.
2) After the 5 minutes, the compressor resumes normal operation.
6.
Error display and load operation when the cold water temperature sensor is faulty
1) When the cold water sensor is OPEN or SHORT
- The bell rings “ding-ding-ding” and then the lower cold water indicator flashes on the FND.
FND indication part
Segment display
When the cold
water temperature
sensor is faulty
2) When the cold water sensor is faulty, the compressor is turned off.
3) When the cold water sensor is OPEN or SHOR
T, the temperature is detected 100 times at an
interval of 10 ms. When the sensor returns to a normal status, the normal operation resumes.
7. Overcooling (Cold water temperature 1°C or lower)
1) When the water is overcooled, the compressor is turned off.