Fault diagnosis
Coway co., Ltd
5-17
2. Extracting room temperature water
Cold water selection switch is
on and the LED is on.
(Ef
fective sensing time 100ms)
Flashes at an interval of 700ms during extraction.
Flsahes at an interval of 100ms from 1.4 seconds before
completing extraction.
Bell: sounds “ding.”
A
set quantity extraction
Stays On during extraction.
Flsahes at an interval of
100ms from 1.4 seconds
before completing extraction.
Extraction switch should be re-entered (150ms) or it goes
of
f after a specified time.
When the re-enter switch is of
f, the extraction is recognized
after 500ms.
Flashes at an interval of 1000ms during extraction.
Flsahes at an interval of 100ms from 1.4 seconds before
completing extraction.
Continuous extraction
Flashes at an interval of
1 second during extraction.
Flsahes at an interval of 100ms
from 1.4 seconds before
completing extraction.
Extraction switch should be re-entered (150ms) or it goes
of
f after extracting water for 60 seconds.
The extraction switch is recognized 500ms after it is
turned of
f.
Extracton switch
(Effective sensing time 100ms)
Extracton switch
(Ef
fective sensing time 2000ms)
Bell:
sounds “ding” at the
beginning.
Bell
sounds
“ding ding”
after 2 seconds.
Bell: sounds “ding.”
CHP-06DL-eng.indb 17 2007-10-22 ソタタ・9:13:20