7
2.3 Product Protection Functions
✓ Reverse polarity protection of DC input
✓ AC and DC Short circuit protection
✓ Anti-islanding protection with bi-directional frequency perturbation
✓ DC Input and AC output over-voltage protection
✓ DC Input over-current protection
✓ DC input insulation against ground monitoring
✓ DC injection of AC output
✓ AC output voltage and frequency monitoring
✓ Leakage current against ground monitoring
✓ External environmental temperature monitoring
✓ IGBT power module temperature monitoring
2.4 Smart Inverter Functions and default Activation
Function
IEEE1547-2014
Rule 21
ISO-NE
Anti-islanding
Enabled
Enabled
Enabled
Low/High Voltage Ride-Though
N/A
Enabled
Disabled
Low/High Frequency Ride-
Though
N/A
Enabled
Enabled
Dynamic Volt/VAR Operation
N/A
Enabled
Disabled
Ramp Rate
N/A
Enabled
Enabled
Fixed Power Factor
N/A
Disabled
Disabled
Reconnect by “Soft-Start”
N/A
Enabled
Enabled
Frequency-Watt
N/A
Enabled
Disabled
Volt/Watt
N/A
Enabled
Disabled