Press key number 4 and the current year setting will show on display. Press key number 2 or 3 to change the
last 2 digits of the year (00 to 99). Press key number 4 with the display showing the year you wish to use and
display will return to “Year”. Press key number 2 to scroll to “Month”.
“Month” - Month Setting (01 to 12)
Press key number 4 and the current 2 digit month setting will show on display. Press key number 2 or 3 to
change the month (01 to 12).
Press key number 4 with the display showing the month you wish to use and display will return to
“Month”. Press key number 2 to scroll to “Day”.
“Day - Day of Month Setting (1 to 31)
Press key number 4 and the current 2 digit day of month setting will show on display. Press key number 2 or
3 to change the day of month (1 to 31). Press key number 4 with the display showing the day you wish to
use and display will return toDay”. Press key number 2 to scroll to “Hour”.
“Hour” - Hour and Minute Setting (0000 to 2359)
Press key number 4 and the current 4 digit hour and minute setting will be displayed (24 hour). The
hour setting will be blinking to indicate it can be changed. Press key number 2 or 3 to change the hour
setting. Press key number 4 to save and the minute setting will start blinking to indicate it can be
changed. Press key number 2 or 3 to change the minute setting. Press key number 4 will save and return
display to “Hour”. Press key number 2 to scroll to “Daylight Savings”.
“Daylight Savings” - Daylight Saving Time Setting
This function is used to set the preferred daylight savings time setting. Press key number 4 will display the
current setting. Press key number 2 or 3 to scroll through the “Daylight savings” options listed:
- OFF”, no daylight savings time changes made.
- Australia”, Australian rules - Set forward 1 hour at 1:00 am on the first Sunday in October; Set
backward 1 hour at 1:00 am on the last Sunday in March.
- Europe”, European rules - Set forward 1 hour at 1:00 am on the last Sunday in March; Set backward 1
hour at 1:00 am on the last Sunday in October.
- North America”, North American rules - Set forward 1 hour at 2:00 am on the second Sunday in March;
Set backward 1 hour at 2:00 am on the first Sunday in November.
Press key number 4 with the display showing the setting you wish to use and display will return to “Daylight
Savings”. Press key number 1 to return to “Time Programming”. Press key number 2 to scroll to next routine.
*”Refrigeration - REFRIGERATION ROUTINE
This function is used to electronically control the refrigeration operations of the vender. Press key number 4 will
enter “Enable #”. Please refer to the Programming Guide for detailed information.
“Setpoint - Set Point Control Routine (Default Temperature 35.0
0
F)
This function is used to set the average product temperature for initial pull down and reload recovery. Press
key number 4 andtt.tx” will show on the display where x is F (Fahrenheit) or C (Celsius) and tt.t is the
degrees.
Press key number 2 to increase or 3 to decrease the number by 1
0
F or 0.5
0
C. With the display showing the
set point temperature you wish to use, press key number 4.
Press key number 2 to scroll to “Storage”.
“Display # - POS Temperature Display Enable Routine
This function is used to enable the POS Temperature to be displayed following the “Ice Cold COCA-COLA
POS message.
Press key number 4 and “ Display Xwill show on the display where x is the current setting. With “X
blinking, press key number 2 or 3 to scroll betweenDisplay 0” disabled or not displayed and Display 1”
enabled or displayed. With the display showing the setting you wish to use, press key number 4. Press key
number 1 to return to “Refrigeration”. Press key number 2 to scroll to next routine.

Table of Contents