Page 15
OPTIONAL ACCESSORIES
INSTALLATION OF RX-16 RECEIVER
The Elite V6 has a high level interface with the RX-16 radio receiver. The addition of this receiver will add wireless
capability to your system in the form of wireless PIR detectors, Wireless Radio-key transmitters and wireless reed
switch transmitters. The RX-16 receiver connects to the same communications port as the keypads and can be
installed , either inside the cabinet, or if preferred, may be installed at a remote location. The RX-16 is available in 2
frequencies, 303.875mhz or 433.92mhz. Multiple RX-16 receivers may be connected to the panel to increase the
effective range if required.
The RX-16 receiver requires 4 cores and can successfully be connected via 0.2mm² unscreened cable over a
distance of up to 100metres. Like the keypads the RX-16 has 12v and 0v terminals for connection to the 12v supply
and CLK and DATA terminals for connection to the communications bus.
The green LED fitted to the RX-16 receiver will indicate when the unit is in "Learn" mode (LED Flashing) or when it is
receiving an actual radio transmission (On Steady)
INSTALLATION OF VOICE or DTMF BOARD
The Elite V6 can also be fitted with a 90 second Voice Board or DTMF module. The Voice board stores either alarm
event messages for Voice dial monitoring and /or status messages for use with Command Control. The DTMF board
provides decoding of keypad numeric entries from a remote telephone. The Elite V6 Voice or DTMF Boards are
installed directly onto the motherboard via the "SERIAL" socket.
Installation procedure for the Voice or DTMF Board module is as follows.
1 Power-down the Elite fully before starting the installation procedure.
2 Carefully plug the Voice or DTMF Board into the SERIAL socket.
3 Power-up the Elite.
Once you have installed the Voice Board you can record your personalised speech messages into the module with
the speech programmer. The programmer plugs onto the 10 way strip connector on the voice board.
To record your messages once the programmer is installed, first press the reset button on the side of the Voice
Board, then hold the programmer about 10 cm away from the mouth and speak clearly at normal level into the
microphone while holding down the "REC" button. When you reach the end of your message release the REC
button. (NOTE: Each individual message must be longer that 2 seconds duration). When recording your voice alarm
message, you must ensure that you clearly identify the origin of the call. You can play the message back through the
programmer by first pressing the reset button then by pressing the "PLAY" button momentarily. Because the Elite V6
can address many individual voice messages you must store individual messages at what is known as recording
slots within the Voice Board. These recording slots are recorded sequentially, one message starting where the other
finishes. Every time you press and release the REC button on the programmer, you create an end of message
marker. These markers are used to define the recording slots within the Voice Board and can be of varying length
according to each message duration.
To re-record your messages you must first press the "RESET" button on the speech module to get back to recording
slot #1. Once you are at slot #1 you can re-record your messages in order as required.
NOTE: When recording multiple messages you only press the “RESET” button once at the beginning then record all
messages sequentially as stated above. When you have finished recording all of your messages you can then press
the “RESET” button to allow play-back of the recording messages for verification purposes.
When you have finished recording your alarm messages, unplug the programmer and the process is complete.