EasyManua.ls Logo

Crow Arrowhead Elite V6 - Area Arm;Disarm Reporting Options

Crow Arrowhead Elite V6
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 52
MANUAL ALARM CONTACT ID REPORTING CODES - P737E-P739E
P737E XXXE “Panic” or “1&3” Keypad Alarm Default = 120
P738E XXXE “Fire” (4&6) Keypad Alarm Default = 110
P739E XXXE “Medical” (7&9) Keypad Alarm Default = 100
ZONE TAMPER ALARM CONTACT ID REPORTING CODES - P741E-P756E
P741E XXXE Input 1 Short Circuit Tamper Default = 137 0 = No Report
P742E XXXE Input 2 Short Circuit Tamper Default = 137
P743E XXXE Input 3 Short Circuit Tamper Default = 137
P744E XXXE Input 4 Short Circuit Tamper Default = 137
P745E XXXE Input 5 Short Circuit Tamper Default = 137
P746E XXXE Input 6 Short Circuit Tamper Default = 137
P747E XXXE Input 7 Short Circuit Tamper Default = 137
P748E XXXE Input 8 Short Circuit Tamper Default = 137
P749E XXXE Input 1 Open Circuit Tamper Default = 137 0 = No Report
P750E XXXE Input 2 Open Circuit Tamper Default = 137
P751E XXXE Input 3 Open Circuit Tamper Default = 137
P752E XXXE Input 4 Open Circuit Tamper Default = 137
P753E XXXE Input 5 Open Circuit Tamper Default = 137
P754E XXXE Input 6 Open Circuit Tamper Default = 137
P755E XXXE Input 7 Open Circuit Tamper Default = 137
P756E XXXE Input 8 Open Circuit Tamper Default = 137
ALARM VOICE MESSAGE MAPPING - P757E - P776E, P789E, P790E
These addresses are used to assign the voice messages to the manually generated Panic, Fire, Medical, battery low
and mains failure messages plus the 16 zone activation's. The voice messages will be replayed over the phone in
response to an alarm activation to those phone numbers which have been assigned Speech Dial format at options
P337E to P342E.
P757E 0-99E Voice Message Mapped to Keypad “Panic” Alarm - Default 0
P758E 0-99E Voice Message Mapped to Keypad “Fire” Alarm - Default 0
P759E 0-99E Voice Message Mapped to Keypad “Medical” Alarm - Default 0
P761E 0-99E Voice Message Mapped to Zone 1 Activation's - Default 1
P762E 0-99E Voice Message Mapped to Zone 2 Activation's - Default 1
P763E 0-99E Voice Message Mapped to Zone 3 Activation's - Default 1
P764E 0-99E Voice Message Mapped to Zone 4 Activation's - Default 1
P765E 0-99E Voice Message Mapped to Zone 5 Activation's - Default 1
P766E 0-99E Voice Message Mapped to Zone 6 Activation's - Default 1
P767E 0-99E Voice Message Mapped to Zone 7 Activation's - Default 1
P768E 0-99E Voice Message Mapped to Zone 8 Activation's - Default 1
P769E 0-99E Voice Message Mapped to Zone 9 Activation's - Default 1
P770E 0-99E Voice Message Mapped to Zone 10 Activation's - Default 1
P771E 0-99E Voice Message Mapped to Zone 11 Activation's - Default 1
P772E 0-99E Voice Message Mapped to Zone 12 Activation's - Default 1
P773E 0-99E Voice Message Mapped to Zone 13 Activation's - Default 1
P774E 0-99E Voice Message Mapped to Zone 14 Activation's - Default 1
P775E 0-99E Voice Message Mapped to Zone 15 Activation's - Default 1
P776E 0-99E Voice Message Mapped to Zone 16 Activation's - Default 1
P789E 0-99E Voice Message Mapped to Mains Failure Alarm - Default 0
P790E 0-99E Voice Message Mapped to Battery Low Alarm - Default 0
MISCELLANEOUS DIALLER OPTIONS
AREA ARM/DISARM REPORTING OPTIONS - P289E
P289E 1-8E Area A Reporting Options - Default 1,2