EasyManua.ls Logo

Crow Arrowhead Elite V6 - Accessing Program Modes

Crow Arrowhead Elite V6
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 16
ACCESSING PROGRAM MODE FOR THE FIRST TIME
GENERAL INFORMATION
There are two program modes in the Elite panel. The first is the “Client” Program Mode to allow a system User to
Add, Change or Delete User Codes.
The second mode is the “Installer” Program Mode. The Installer Program Mode allows ALL programmed data to
be changed. Access to both Modes is described below.
ACCESS TO INSTALLER PROGRAMMING ON POWER UP
When power is applied to the controller for the first time, with the panel tamper input open and none of the
Areas either fully Armed or in Stay mode, the panel will inhibit tamper alarms and ready the panel to enter
INSTALLATION PROGRAM Mode (unless the Installer Lock-out option P310E7E has previously been enabled). At
this point you can go to any keypad which is connected to the panel and;
Press –PROGRAM”-”ENTER”
which will automatically put that keypad into Installation Program mode, Program LED Flashing. (NOTE: Only one
keypad can be in Program mode at any time)
ACCESS TO PROGRAM MODES FROM RUN MODE
Before you can enter program mode from the normal Run Mode, the panel must be disarmed and not in stay mode.
Then;
Press <PROGRAM> - <Code 1 (or Master Code)> - <ENTER>
Program light steady
Note: Default Master Code (Code 1) is 1,2,3
You are now in Client Program Mode. When you are in Client programming mode you have access to program
addresses P1E to P50E (user code programming). To Enter Installer Program Mode from Client Program Mode;
Press <PROGRAM> - <Install Code> - <ENTER>
Program light flashing
Note: Default Installer Code (P249E) is 0,0,0,0,0,0
By default the installer can go directly to Installer Program Mode from Normal Run mode provided No Areas are
Armed or in Stay Mode. The Installer Mode direct option can be disabled at address P310E Option 6.
HOW TO PROGRAM YOUR ELITE
The programming sequence always follows this pattern once you have accessed one of the Program Modes;
<PROGRAM> - <1,2,3 or 4 digit address> - <ENTER>
3 short beeps if OK - 1 long beep if error
The LED’s will display current value or status
Enter the new value or option
<New Value> - <ENTER>
3 short beeps if OK - 1 long beep if error
An example of programming is shown below. Here we are programming User Code 23 (P23E) with the code
number of 2580.
P 23 E 2,5,8,0 E
In this example the <P> represents the PROGRAM key, <23> represents the actual program address, 2580 is the
data and <E> represents the ENTER key.
TO CLEAR PROGRAM INFORMATION (From Installation Mode Only)
There are multiple options available for clearing program information (Reset to
defaults). These are detailed on page 41.