LOCAL COMMAND CONTROL OF OUTPUTS
If a command control code for outputs is programmed (P371E) and the output/s are allowed to be locally controlled
(P201-P208, option 6) then entering the 4 digit code at a keypad will blank the display and the zone LED’s will now
indicate the output status e.g. if output 1 is on zone 1 LED will be on. By now pressing the “1” button at the panel
keypad, output 1 can be turned off provided it is allowed to be locally controlled. To leave local command control
mode simply press the “Enter” button and the keypad will return to normal operation. If option 8 at addresses P301,
P401 or P501 are on, you can access this Local Command Control mode directly by simply pressing the “Control”
button at the keypad followed by the output number/s that are allowed to be controlled.