Page 35
P540E 0-999E Area "A" Special Stay Mode entry delay - Default 20 seconds
P541E 0-999E Area "B" Special Stay Mode entry delay - Default 20 seconds
P542E 0-999E Area "C" Special Stay Mode entry delay - Default 20 seconds
DAY ZONE TO KEYPAD BUZZER TIMES - P543E to P545E
P543E 1-999E Area "A" Day Zone keypad buzzer duration - Default 2 seconds
P544E 1-999E Area "B" Day Zone keypad buzzer duration - Default 2 seconds
P545E 1-999E Area "C" Day Zone keypad buzzer duration - Default 2 seconds
DAY ZONE TO OUTPUT TIMES - P546E to P548E
P546E 1-999E Area "A" Day Zone to Output duration - Default 2 seconds
P547E 1-999E Area "B" Day Zone to Output duration - Default 2 seconds
P548E 1-999E Area "C" Day Zone to Output duration - Default 2 seconds
OUTPUT RESET TIMES - P551E to P558E
P551E 0-999E Output #1 reset time - Default 600 seconds (10 min)
P552E 0-999E Output #2 reset time - Default 600 seconds (10 min)
P553E 0-999E Output #3 reset time - Default 600 seconds (10 min)
P554E 0-999E Output #4 reset time - Default 600 seconds (10 min)
P555E 0-999E Output #5 reset time - Default 0 (latching)
P556E 0-999E Output #6 reset time - Default 0 (latching)
P557E 0-999E Output #7 reset time - Default 0 (latching)
P558E 0-999E Output #8 reset time - Default 0 (latching)
MAINS FAIL REPORTING DELAY TIME - P559E
P559E 0-999E Mains Fail Dialler Report Delay - Default 600 seconds
ZONE ALARM REPORT DELAY TIME - P560E
P560E 0-999E Zone Alarm Report Delay to Dialler - Default 0 seconds
OUTPUT DELAY ON TIMES - P561E to P568E
P561E 0-999E Output #1 delay on timer - Default 0 (instant)
P562E 0-999E Output #2 delay on timer - Default 0 (instant)
P563E 0-999E Output #3 delay on timer - Default 0 (instant)
P564E 0-999E Output #4 delay on timer - Default 0 (instant)
P565E 0-999E Output #5 delay on timer - Default 0 (instant)
P566E 0-999E Output #6 delay on timer - Default 0 (instant)
P567E 0-999E Output #7 delay on timer - Default 0 (instant)
P568E 0-999E Output #8 delay on timer - Default 0 (instant)
ZONE INACTIVITY DELAY TIME - P569E
P569E 0-999E Zone Inactivity Timer (0-999 hours) - Default 120 hours
SUPERVISED RADIO SIGNAL TIME - P570E
P570E 0-999E Supervised Radio Timer (0-999 minutes) - Default 240 minutes
OUTPUT PULSE TIMES - P571E to P578E
P571E 0-999E Output #1 pulse time -Default 0 (0 = Minimum 0.1 sec pulse) Times are in 1/10 second
P572E 0-999E Output #2 pulse time -Default 0 (0 = Minimum 0.1 sec pulse) increments
P573E 0-999E Output #3 pulse time -Default 0 (0 = Minimum 0.1 sec pulse)
P574E 0-999E Output #4 pulse time -Default 0 (0 = Minimum 0.1 sec pulse)
P575E 0-999E Output #5 pulse time -Default 0 (0 = Minimum 0.1 sec pulse)
P576E 0-999E Output #6 pulse time -Default 0 (0 = Minimum 0.1 sec pulse)
P577E 0-999E Output #7 pulse time -Default 0 (0 = Minimum 0.1 sec pulse)
P578E 0-999E Output #8 pulse time -Default 0 (0 = Minimum 0.1 sec pulse)