ZONE BYPASS SCENARIO MAPPING - P581E - P596E
These addresses are used to map zone bypasses (isolations) from each of the 16 possible alarm zones to one of the
4 possible reporting scenarios. If a value of zero (0) is assigned at an address in this block, bypasses from that zone
will not be reported by the panel.
P581E 1-4E Zone 1 Bypass mapped to Scenario 1-4 - Default 1
P582E 1-4E Zone 2 Bypass mapped to Scenario 1-4 - Default 1
P583E 1-4E Zone 3 Bypass mapped to Scenario 1-4 - Default 1
P584E 1-4E Zone 4 Bypass mapped to Scenario 1-4 - Default 1
P585E 1-4E Zone 5 Bypass mapped to Scenario 1-4 - Default 1
P586E 1-4E Zone 6 Bypass mapped to Scenario 1-4 - Default 1
P587E 1-4E Zone 7 Bypass mapped to Scenario 1-4 - Default 1
P588E 1-4E Zone 8 Bypass mapped to Scenario 1-4 - Default 1
P589E 1-4E Zone 9 Bypass mapped to Scenario 1-4 - Default 1
P590E 1-4E Zone 10 Bypass mapped to Scenario 1-4 - Default 1
P591E 1-4E Zone 11 Bypass mapped to Scenario 1-4 - Default 1
P592E 1-4E Zone 12 Bypass mapped to Scenario 1-4 - Default 1
P593E 1-4E Zone 13 Bypass mapped to Scenario 1-4 - Default 1
P594E 1-4E Zone 14 Bypass mapped to Scenario 1-4 - Default 1
P595E 1-4E Zone 15 Bypass mapped to Scenario 1-4 - Default 1
P596E 1-4E Zone 16 Bypass mapped to Scenario 1-4 - Default 1
LOW ZONE TAMPERS SCENARIO MAPPING - P601E - P608E
This group of addresses is used to map the eight possible low zone tampers to one of the four possible reporting
scenarios. If a value of zero (0) is assigned at an address in this block, low tampers from that zone will not be
reported by the panel. Low Zone Tamper is a short circuit input.
P601E 1-4E Short Circuit Tamper Alarm on Input 1 mapped to Scenario 1-4 - Default 1
P602E 1-4E Short Circuit Tamper Alarm on Input 2 mapped to Scenario 1-4 - Default 1
P603E 1-4E Short Circuit Tamper Alarm on Input 3 mapped to Scenario 1-4 - Default 1
P604E 1-4E Short Circuit Tamper Alarm on Input 4 mapped to Scenario 1-4 - Default 1
P605E 1-4E Short Circuit Tamper Alarm on Input 5 mapped to Scenario 1-4 - Default 1
P606E 1-4E Short Circuit Tamper Alarm on Input 6 mapped to Scenario 1-4 - Default 1
P607E 1-4E Short Circuit Tamper Alarm on Input 7 mapped to Scenario 1-4 - Default 1
P608E 1-4E Short Circuit Tamper Alarm on Input 8 mapped to Scenario 1-4 - Default 1
HIGH ZONE TAMPERS SCENARIO MAPPING - P609E - P616E
This group of addresses is used to map the eight possible High zone tampers to one of the four possible reporting
scenarios. If a value of zero (0) is assigned at an address in this block, high tampers from that zone will not be
reported by the panel. High Zone Tamper is an open circuit input.
P609E 1-4E Open Circuit Tamper Alarm on Input 1 mapped to Scenario 1-4 - Default 1
P610E 1-4E Open Circuit Tamper Alarm on Input 2 mapped to Scenario 1-4 - Default 1
P611E 1-4E Open Circuit Tamper Alarm on Input 3 mapped to Scenario 1-4 - Default 1
P612E 1-4E Open Circuit Tamper Alarm on Input 4 mapped to Scenario 1-4 - Default 1
P613E 1-4E Open Circuit Tamper Alarm on Input 5 mapped to Scenario 1-4 - Default 1
P614E 1-4E Open Circuit Tamper Alarm on Input 6 mapped to Scenario 1-4 - Default 1
P615E 1-4E Open Circuit Tamper Alarm on Input 7 mapped to Scenario 1-4 - Default 1
P616E 1-4E Open Circuit Tamper Alarm on Input 8 mapped to Scenario 1-4 - Default 1
SYSTEM EVENTS SCENARIO MAPPING - P421E - P438E
This group of addresses is used is used to map System Events as listed below to one of the four possible reporting
scenarios. If a value of zero (0) is assigned at an address in this block, that event will not be reported by the panel.
P421E Area A Arm/Disarm reports mapped to scenario 1-4 default 1
P422E Area B Arm/Disarm reports mapped to scenario 1-4 default 1
P423E Area C Arm/Disarm reports mapped to scenario 1-4 default 1
P424E Keypad Panic (& buttons 1 & 3) mapped to scenario 1-4 default 1
P425E Keypad Fire (buttons 4 & 6) mapped to scenario 1-4 default 1
P426E Keypad Medical (buttons 7 & 9) mapped to scenario 1-4 default 1
P427E Battery low mapped to scenario 1-4 default 1